介质:兼容液体
接液材质:杆,连接器,浮子
温度限制:Buna-N浮子: 0~180°F (-18~82°C); 油: -40~230°F (-40~110°C); SS 浮子: -40~300°F (-40~149°C).
电气连接:24" (61 cm) free leads; #22 AWG TFE and #18 AWG polymeric.
安装方向:垂直±30°.
选型表
EXAMPLE | F7-MS | B | 3 | 5 | F3 | 1 | 04.25 | 07.50 | 11.66 | 15.75 | 20.00 | 24.10 | 32.00 | J | Series F7-MSB3-5F31-04.25-07.50-11.66-15.75-20.00- 24.10-32.00-J Multi-Station Level Switch, brass with beryllium copper stops, 2" NPT, 6 switch points, 316SS float, min. s.g. 0.75, max. pressure 750 psi, SPST, .17A @ 120VAC, L6 set point distance 4.25", L5 set point distance 7.5", L4 set point distance 11.66", L3 set point distance 15.75", L2 set point distance 20", L1 set point distance 24.1", 32" overall length, with junction box for wire leads, NEMA 4. |
SERIES | F7-MS | Multi-Station Level Switch | |||||||||||||
STEM & CONN. MATERIAL | B S | Brass with Beryllium Copper Stops 316SS with SS Armco PH-15-7MO Stops | |||||||||||||
CONNECTION TYPE | 1 2 3 4 5 | 1/2" NPT (float F2 and F3 only) 1-1/4" NPT (float F1 only) 2" NPT 3" 150# Flange, Carbon Steel (float F2 and F3 only) 3" 150# Flange, 316SS (float F2 and F3 only) | |||||||||||||
NUMBER OF SWITCH POINTS | 1 2 3 4 5 6 | 1 Switch Point 2 Switch Points 3 Switch Points 4 Switch Points 5 Switch Points 6 Switch Points | |||||||||||||
FLOAT TYPE | F1 F2 F3 | Buna-N, Min. S.G. 0.75, Max. Pressure 150 psi (10.3 bar) Buna-N, Min. S.G. 0.55, Max. Pressure 150 psi (10.3 bar) 316SS, Min. S.G. 0.75, Max. Pressure 750 psi (51.7 bar) [Units >72": 300 psi (20.7) bar] | |||||||||||||
SWITCH TYPE | 1 2 3 | SPST, .1 7A @ 12 0VAC SPST, .8 A @ 120 VAC SPDT, .17 A @ 120 VAC NO switch is standard. For NC place and "*" after the corresponding set point distance in the model number. | |||||||||||||
SET POINT DISTANCE (L6) | 00.00 | In inches referenced from bottom of connection. Example: 04.25 would be 4.25" from the bottom of the process connection. | |||||||||||||
SET POINT DISTANCE (L5) | 00.00 | In inches referenced from bottom of connection. Example: 07.50 would be 7.50" from the bottom of the process connection. | |||||||||||||
SET POINT DISTANCE (L4) | 00.00 | In inches referenced from bottom of connection. Example: 11.66 would be 11.66" from the bottom of the process connection. | |||||||||||||
SET POINT DISTANCE (L3) | 00.00 | In inches referenced from bottom of connection. Example: 15.75 would be 15.75" from the bottom of the process connection. | |||||||||||||
SET POINT DISTANCE (L2) | 00.00 | In inches referenced from bottom of connection. Example: 20.00 would be 20" from the bottom of the process connection. | |||||||||||||
SET POINT DISTANCE (L1) | 00.00 | In inches referenced from bottom of connection. Example: 24.10 would be 24.1" from the bottom of the process connection. | |||||||||||||
OVERALL LENGTH (LO) | 00.00 | Maximum overall length with Connection Type 1: 36" (931.4 cm); Connection Type 2: 60" (152.4 cm); Connection Types 3, 4 or 5: 140" (355.6 cm). Minimum length is L1 + D. | |||||||||||||
OPTIONS | J | Junction Box for Wire Leads, NEMA 4 |