选型表
EXAMPLE | 38R | D | A1 | V | A | 3 | 2 | 1 | 01 | 08 | 1 | R01 | Series 38R-DA1VA32-101081-R01 Self-Acting Temperature Control Valve, 2-way, direct acting, 1/2" connection with 1/8" port, single seat, linear, bronze body, 316SS trim, non-indicating actuator, brass union hub, copper bulb & 8' capillary, 316SS well, range 20 to 70°F. |
SERIES | 38R | Self-Acting Temperature Control Valve | |||||||||||
ACTION | 0 3 D R | Replacement Actuator Only 3-way 2-way Direct Acting 2-way Reverse Acting | |||||||||||
CONNECTION & PORT SIZE | A1 A2 A3 A4 B1 B2 B3 B4 B5 C1 C2 C3 C4 C5 C6 00 01 02 03 04 05 06 07 08 09 10 | 1/2" Connection with 1/8" Port 1/2" Connection with 3/16" Port 1/2" Connection with 1/4" Port 1/2" Connection with 3/8" Port 3/4" Connection with 1/8" Port 3/4" Connection with 3/16" Port 3/4" Connection with 1/4" Port 3/4" Connection with 3/8" Port 3/4" Connection with 1/2" Port 1" Connection with 1/8" Port 1" Connection with 3/16" Port 1" Connection with 1/4" Port 1" Connection with 3/8" Port 1" Connection with 1/2" Port 1" Connection with 3/4" Port 1/2" Full Port 3/4" Full Port 1" Full Port 1-1/4" Full Port 1-1/2" Full Port 2" Full Port 2-1/2" Full Port 3" Full Port 4" Full Port 5" Full Port 6" Full Port | |||||||||||
VALVE SEAT | 0 V W | Replacement Actuator Only Single Seat Double Seat | |||||||||||
VALVE PLUG TYPE (Internal) | 0 A | Replacement Actuator Only Linear | |||||||||||
BODY MATERIAL | 0 1 2 3 4 | Replacement Actuator Only Cast Iron Cast Steel Bronze 316SS | |||||||||||
TRIM MATERIAL (Internal) | 0 1 2 | Replacement Actuator Only Bronze 316SS | |||||||||||
ACTUATOR | 0 1 2 3 | Replacement Body Only Non-Indicating Indicating Fail-Safe | |||||||||||
BULB & CAPILLARY | 00 01 02 03 04 05 06 07 08 09 10 | Replacement Body Only Brass Union Hub, Copper Bulb & Capillary SST Union Hub, SST Bulb & Capillary Brass Adjustable Union Hub, Copper Bulb & Capillary SST Adjustable Union Hub, SST Bulb & Capillary Copper Bulb & Capillary Only SST Bulb & Capillary Only Bulb & Capillary Only Copper w/FEP Covering Bulb & Capillary Only SST w/FEP Covering Brass Union Hub, Copper Bulb & Capillary SST Armor SST Union Hub, SST Bulb & SST Capillary SST Armor | |||||||||||
CAPILLARY LENGTH | 00 08 12 16 20 24 28 32 36 40 44 48 52 | Replacement Body Only 8' 12' 16' 20' 24' 28' 32' 36' 40' 44' 48' 52' | |||||||||||
WELL | 0 1 2 | None 316SS Brass | |||||||||||
RANGE | 000 R01 R02 R03 R04 R05 R06 R07 R09 R10 R11 R12 R13 R14 R81 R82 R83 R84 R85 R86 R89 R90 R91 R92 R93 R94 R95 R96 | Replacement Body Only 20 to 70°F (-10 to 20°C) 40 to 90°F (5 to 30°C) 30 to 115°F (0 to 45°C) 50 to 140°F (10 to 60°C) 75 to 165°F (25 to 70°C) 105 to 195°F (40 to 90°C) 125 to 215°F (55 to 100°C) 155 to 250°F (70 to 120°C) 200 to 280°F (9 to 135°C) 225 to 315°F (110 to 155°C) 255 to 370°F (125 to 185°C) 295 to 420°F (145 to 215°C) 310 to 440°F (155 to 225°C) 40 to 65°F (5 to 20°C) 55 to 80°F (15 to 25°C) 65 to 90°F (20 to 30°C) 81 to 110°F (25 to 40°C) 90 to 115°F (30 to 45°C) 110 to 140°F (40 to 60°C) 140 to 175°F (60 to 80°C 170 to 195°F (80 to 90°C) 190 to 210°F (85 to 100°C) 205 to 225°F (95 to 105°C) 215 to 250°F (100 to 120°C) 230 to 265°F (110 to 130°C) 245 to 280°F (120 to 135°C) 270 to 300°F (135 to 150°C) |