低信噪比。
工厂安装和预先管道在法兰管道部分(套管)。
标准结构包括镀锌外壳和6063-t5阳极氧化铝流量传感器。
标准气流站可(在空气中)在350°F以下的温度下连续运行,或在400°F以下的温度下间歇运行。
精度:根据公布的建议安装时,在实际流量的2%以内
K-因子:0.97.
风速范围:100~10,000 FPM (0.51-51 m/s).
接液材质:单元:6063-T5阳极氧化铝;外壳:16 Ga G90镀锌钢。
温度限制:镀锌外壳和铝件:350°F(177°C)连续作业(空气中)400°F(204°C)间歇操作(空气中)。
湿度:全站 0-100%非结露.
过程连接:1/4"压缩配件。
选型表
矩形和椭圆模型:
EXAMPLE | FLST | O | 12 | X16 | IM | Series FLST-R12X16-IM Duct Mounted Airflow Measurement Station, 12" x 16" oval duct, with internal pressure connections. |
SERIES | FLST | Duct Mounted Airflow Measurement Station | ||||
CONFIGURATION | O R | Oval Rectangular | ||||
DUCT HEIGHT | 8 10 12 14 16 18 20 22 24 26 28 29 30 32 34 36 38 40 44 46 48 52 56 60 64 66 72 78 84 90 94 96 102 108 114 120 250MM 300MM 350MM 400MM 410MM 450MM 500MM 510MM 600MM 625MM 650MM 700MM 800MM 1000MM 1200MM 1250MM 1500MM 1800MM 2000MM | 8" 10" 12" 14" 16" 18" 20" 22" 24" 26" 28" 29" 30" 32" 34" 36" 38" 40" 44" 46" 48" 52" 56" 60" 64" 66" 72" 78" 84" 90" 94" 96" 102" 108" 114" 120" 250MM 300MM 350MM 400MM 410MM 450MM 500MM 510MM 600MM 625MM 650MM 700MM 800MM 1000MM 1200MM 1250MM 1500MM 1800MM 2000MM | ||||
DUCT WIDTH | X8 X10 X12 X14 X16 X18 X19 X20 X22 X24 X26 X28 X29 X30 X32 X34 X35 X36 X38 X40 X41 X42 X44 X46 X47 X48 X50 X52 X54 X56 X58 X60 X62 X66 X72 X78 X84 X90 X96 X98 X102 X108 X114 X120 X250MM X300MM X350MM X400MM X450MM X500MM X510MM X560MM X600MM X650MM X700MM X750MM X755MM X800MM X825MM X915MM X1000MM X1015MM X1100MM X1200MM X1250MM X1300MM X1500MM X1600MM X1800MM X2000MM X2200MM | 8" 10" 12" 14" 16" 18" 19" 20" 22" 24" 26" 28" 29" 30" 32" 34" 35" 36" 38" 40" 41" 42" 44" 46" 47" 48" 50" 52" 54" 56" 58" 60" 62" 66" 72" 78" 84" 90" 96" 98" 102" 108" 114" 120" 250MM 300MM 350MM 400MM 450MM 500MM 510MM 560MM 600MM 650MM 700MM 750MM 755MM 800MM 825MM 915MM 1000MM 1015MM 1100MM 1200MM 1250MM 1300MM 1500MM 1600MM 1800MM 2000MM 2200MM | ||||
OPTIONS | F IM SS1 SS2 SS3 | 1-1/2" Flange for Oval Mount Station Only Internal Pressure Connections 316 SST Elements with 16 GA Galvanized Casing 316 SST Elements with 16 GA 304 SST Casing 316 SST Elements with 16 GA 316 SST Casing |
圆形:
EXAMPLE | FLST | C | 12 | IM | Series FLST-C12-IM Duct Mounted Airflow Measurement Station, 12" diameter duct, with internal pressure connections. |
SERIES | FLST | Duct Mounted Airflow Measurement Station | |||
CONFIGURATION | C | Circular | |||
DUCT DIAMETER | 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 40 44 48 54 60 64 66 72 78 84 90 96 102 108 114 120 600MM 750MM 950MM 1800MM | 8" 10" 12" 14" 16" 18" 20" 22" 24" 26" 28" 30" 32" 34" 36" 40" 44" 48" 54" 60" 64" 66" 72" 78" 84" 90" 96" 102" 108" 114" 120" 600MM 750MM 950MM 1800MM | |||
OPTIONS | IM SS1 SS2 SS3 | Internal Pressure Connections 316 SST Elements with 16 GA Galvanized Casing 316 SST Elements with 16 GA 304 SST Casing 316 SST Elements with 16 GA 316 SST Casing |